Adjustment of the drive, Value function – DE-STA-CO F5-B AC Inverter Drive User Manual

Page 42

Advertising
background image

42

Adjustment of the Drive

If the braking time depends on the actual frequency (CP.20 = 2...7), it is
calculated as follows:

CP.21 x f

real

t

Brake

=

–––––––––
100 Hz

Otherwise the braking time corresponds to CP.21.

Adjustment range:

0.00...100.00 s

Resolution:

0.01 s

Factory setting:

0.10 s

DC-braking Time

f

t

100 Hz

f

actual

t

Brake

CP.21

CP.22 determines the function of Relay Output 2.
Relay output 2 (terminal X2A.27...X2A.29)

The switching level of CP.22 is CP.23!

Relay output 2

Value

Function

0

No function

1

On; active when unit has voltage applied to it

2

Run signal; also by DC-braking

3

Ready signal (no error)

4

Fault relay

5

Fault relay (no auto-reset)

6

Warning or error message at abnormal stopping

7

Overload alert signal

8

Overtemperature alert signal power modules

9

External Overtemperature alert signal motor

10

Motor thermal relay tripped (OH2)

11

Overtemperature alert signal interior (OHI)

12

Cable breakage on analog input 1 (4...20 mA)

13

Cable breakage on analog input 2 (4...20 mA) {F5G only}

14

Max. constant current (stall, CP.15) exceeded

15

Max. ramp current (LA-Stop CP.14) exceeded

16

DC-braking active

17

Power off

18

Motor brake control

19

PID control difference > switching level {F5G only}

20

Actual value=set value (CP.2=Fcon, rcon; not at noP, LS
error,SSF)

21

Accelerate (CP.2 = FAcc, rAcc, LAS)

22

Decelerate (CP.2 = FdEc, rdEc, LdS)

23

Real direction of rotation = set direction of rotation

Advertising