Bb6000 operational dimensions, Determining required bar length – Climax BB6000 PORTABLE LINE BORING MACHINE User Manual

Page 15

Advertising
background image

6/00 15

BB6000 Operational Dimensions

Specifications in inches (mm)

Specifications subject to change without notice.

For precision dimensions consult your factory representative.

Determining Required Bar Length

Total required bar length = 21 (533.4) + distance to bore + (2x standoff length)

1

Recommended minimum standoff length for boring = 7.5 (190.5)

2

Recommended minimum standoff for facing = 14.0 (355.6)

Maximum recommended unsupported

bar length is 5 ft. (1.5 m)

7.25
(184.2)

Standoff

1,2

5.0

(127.0)

5.0

(127.0)

Axial feed
assembly

Rotational drive
assembly

Hydraulic motor

End-mount bearing
support assembly

Boring bar

Boring head and
tool carrier

End-mount
bearing
support
assembly

Standoff

1,2