Installation – Burkert Type 2101 User Manual

Page 9

Advertising
background image

9

Installation

Type 2101

6.5. General technical data

media

Control medium

Neutral gases, air

Flow media

Water, alcohol, fuel, hydraulic liquids,
saline solutions, lye, organic solvents

materials and
connections

see data sheet or operating instructions

installation

as required, preferably with actuator in
upright position.

protection class

IP67 in accordance with IEC 529 /
EN 60529

6.6. control functions (cf)

A

1(P)

2(A)

Normally closed by spring action.

B

1(P)

2(B)

Normally open by spring action.

I

1(P)

2(A)

Actuating function via reciprocal pressurization.

Tab. 3: Control functions

7. insTallaTion

7.1. safety instructions

Danger!

risk of injury from high pressure!
• Before loosening the lines and valves, turn off the pressure and

vent the lines.

Warning!

risk of injury from improper installation!
• Installation may be carried out by authorized technicians only

and with the appropriate tools!

risk of injury from unintentional activation of the system and
an uncontrolled restart!
• Secure system from unintentional activation.
• Following installation, ensure a controlled restart.
for control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
• To ensure a controlled restart, first pressurize the device with

pilot pressure, then switch on the medium.

risk of injury from moving parts in the device!
• Do not reach into openings.

english