Meter/Solenoid Electrical Connection (Refer to Figure 5)

Connect the drain solenoid wire harness to the solenoid valve.

Insert the flow meter cable into the socket on the flow meter

If installing with the backflush kit:

a. Remove the two transformer leads from the terminal strip (terminals 4 and 5) and replace them with the leads

from the higher-rated transformer provided in the kit.

b. Install inlet solenoid’s wiring harness (backflush kit) to the control board. The inlet solenoid leads should be

installed in the same terminal locations as the drain solenoid (1-green, 2-black, 3-white). DO NOT connect the

wiring harness to the solenoid at this time.

Plug the power cord transformer into a 120V GFI outlet.

1.

2.

3.

4.

Installation Instructions

42209_REVB

2

4

1

5

3

6

1

B

T

B

24 VAC Transformer

Solenoid Harness

Black

Black
Green

White
White

Black

Yellow

White
Wt/Blk

Figure 5: Meter/Solenoid Electrical Connection Diagram