Service & Maintenance

When to call the Dealer

If problems are experienced with the installation or operation of the FreshPoint™, refer to the troubleshooting

guide in this service manual, or contact your FreshPoint™ Distributor for assistance.

Monitoring

If changes to the flow rate or pressure are noticed, contact the installer to get recommendations on changing

flushing settings, and/or have the system evaluated by the installer. Many factors can cause a change in pressure.

As water temperature decreases, the flow available from the FreshPoint™ system will also decrease for the

same inlet pressure. The flow rate will drop or rise approximately 3% for a corresponding 1° (1.8°F) drop or rise

in water temperature. Prefilter plugging will cause a decrease in available pressure. Additionally, if a noticeable

loss of pressure is detected over time, the current flushing schedule may not be sufficient to prevent fouling, and

additional flushing will be required. Refer to the Troubleshooting section in this service manual to address this and

other issues.

Prefilter Changes

The prefilter should be changed as recommended by the manufacturer. Generally, change the cartridge when a

decrease in pressure is noted, or after 6 months installed.

Membrane Maintenance

The FreshPoint™ membrane must be kept in a wetted condition. Once installed or during service and

maintenance activities, do not allow the FreshPoint™ membrane to sit completely drained for extended periods

(greater than 12 hours). Failure to do so may damage the system. If the FreshPoint™ is drained or out of

service for an extended period of time, the installer/dealer should put a preservative into the system to keep

the membrane wetted and prevent microbial growth. A 0.1% sodium bisulfite solution is recommended. A 0.1%

sodium bisulfite solution would be 1 gram of sodium bisulfite added to one liter of water (approximately ten liters

are required).

Prior to putting the FreshPoint™ back into service, the system should be flushed and sanitized per the

instructions in the Installation section of this service manual.

Membrane Cleaning

Membrane cleaning is required when the surface of the membrane and membrane pores become fouled. This

is most often detected by a loss of flow rate. The FreshPoint™ membranes should be maintained in a clean

condition, unfouled by particulate matter, precipitates or biological growth. Contact your FreshPoint™ Distributor

for cleaning.