Installation Instructions

System Sanitizing - No Prefilter Installed

CAUTION: Sodium hypochlorite (bleach) is used for disinfection. The user should acquaint themselves

with the appropriate safety precautions for storage and handling of the chemicals being used. USE ONLY

SODIUM HYPOCHLORITE. DO NOT USE BLEACHES CONTAINING ANY OTHER COMPOUNDS.

Close the inlet valve of the bypass plumbing arrangement. If installing with backflush kit, disconnect the wiring

harness from the inlet solenoid valve or product tank.
If the FreshPoint™ system is equipped with a backflush tank, initiate successive flushes by pressing the

Extra Cycle button on the timer until the flush tank is empty. Isolate the backflush tank by closing the tank

isolation valve.

CAUTION: Any product or backflush tank needs to be isolated during disinfection. The

chemicals use in disinfection are at a higher concentration than recommended for these tanks, and

are likely to cause damage to the tanks if exposed.
Open a faucet near the FreshPoint™ system to ensure that the plumbing system is depressurized.
Separate the drain plumbing from the FreshPoint™ housing at the union.
Drain the FreshPoint™ housing into a bucket by loosening the supply port union or using the recommended

integrity test port.
Tighten the supply port or close integrity test valve.
Through the drain port fill the FreshPoint™ housing with a solution containing chlorine at 100 mg/l (1 1/2

teaspoons of unscented bleach in 1 gallon of clean water). See figure 6.
Reconnect the drain plumbing union.
Open the inlet valve of the bypass valve arrangement and allow water to flow until a chlorine smell is detected

in the water flowing from the open faucet.
Close the open faucet and allow the

system to soak for one hour.
Initiate a system flush by pressing the

Extra Cycle button on the timer.
Open the service faucet and allow the

water to flow until the chlorine smell is not

detected.
Use a test kit to confirm that the chlorine

level is below 4 ppm (ideally below 1 ppm).
Repressurize the system by opening the

closest faucet, and slowly opening the inlet

valve of the bypass plumbing arrangement.

Expel air from the feed side by pressing

the Extra Cycle button several times.
Close the faucet. Open the tank isolation

valve and reconnect the inlet solenoid

valve to the wiring harness, if applicable.

1.

2.

3.
4.
5.

6.
7.

8.
9.

10.

11.

12.

13.

14.

15.

Add Sanitizing Solution

Figure 6: Adding Sanitizing Solution