Troubleshooting

Problem

Possible Cause

Correction

1.System controller does not have

power.

A. The system is not plugged

in.

A. Plug the system controller in.

2. There is no product water flow to

the house.

A. Bypass valves are not in the

correct positions to allow water

flow to the house, or supply

water is unavailable.

A. Restore supply flow to the system.

B. Cartridge in prefilter is

plugged.

B. Replace or clean the filter cartridge.

C. FreshPoint™ membrane is

fouled.

C. Contact your FreshPoint™ dealer for

service.

3. There is low flow or pressure

available.

A. FreshPoint™ is flushing.

A. Wait for flush to end. If desired, have

a pressure tank installed after system

to maintain pressure during flush. If

flushing continuously, see #4 below.

B. Unit is not flushing

frequently enough.

B. Decrease the volume between

flushes, and/or increase the flush time.

C. Inlet water pressure is too

low.

C. Boost the inlet water pressure.

D. Cartridge in prefilter is

plugged.

D. Replace or clean the filter cartridge.

E. FreshPoint™ membrane is

fouled.

E. Contract your FreshPoint™ dealer for

service.

F. Incoming water temperature

is too low.

F. Contact your FreshPoint™ dealer for

options to compensate for low water

temperature.

4. System is flushing continuously.

A. Drain solenoid valve is stuck

open.

A. Replace the drain solenoid valve.

B. System controller circuit

board is sending flush signal

continuously.

B. Contact your FreshPoint™ dealer for

service.

5. System is not flushing.

A. The system is not plugged

in.

A. Plug the system controller in.

B. Drain solenoid valve is stuck

closed.

B. Replace the solenoid valve.

C. Meter is not reading flow.

C. Check the connection of meter cable

to meter, secure if necessary.

D. System controller circuit

board is not sending flush

signal.

D. Contact your FreshPoint™ dealer for

service.

6. Meter is not reading flow.

A. Meter cable is not secured

to meter body.

A. Check the connection of meter cable

to meter, and secure if necessary.

B. Meter or controller are

malfunctioning.

B. Contract your FreshPoint™ dealer for

service.