Installation instructions, Page 8 standard installation (forward flush only) – Hydrotech FreshPoint U440 Ultrafiltration System User Manual

Page 8

Advertising
background image

Page 8

Standard Installation (Forward Flush only)

A standard installation clears the membrane periodically by opening a drain port, and allowing the feed stream

flow in its normal direction, but at a faster rate. The flow goes in and out of the end of the fiber instead of through

the membrane, and the foulant is cleaned off the membrane and out of the unit to drain.

Connect the FreshPoint™ to the household plumbing supply as shown in Figure 1. It is recommended that the

plumbing include a system bypass for future service. A 200 um sediment pre-filter is recommended. For ease of

membrane element replacement, unions are recommended as indicated on Figure 1.

NOTE: Installations without a pressure tank may experience drops in pressure/flow to the home during a

flush cycle.

Installation Instructions

Figure 1: Tankless Installation

Drain Flow Control

(Note Flow Direction)

Flow Meter Housing

(Note Flow Direction)

Drain

Piping Must

Include

Code-Compliant

Air Gap

1/4” Ball Valve Pressure Tap

for Membrane Integrity Testing

(Recommended)

Inlet Flow Control

(Note Flow Direction)

Pre-filter (Recommended)

Inlet Valve

Bypass Valve

Inlet

Outlet

Outlet Valve

42605_REVA