Flushing schedule & installation instructions, Page 6, Flushing schedule – Hydrotech FreshPoint U440 Ultrafiltration System User Manual

Page 6

Advertising
background image

Page 6

Flushing Schedule & Installation Instructions

Flushing Schedule

The FreshPoint™ is flushed on a schedule dependent on the quality of water being treated.
Default Factory Settings
Flush Frequency:

100 gallons

Flush Duration:

0.5 minutes

Day Override:

1 Day

These settings may need to be adjusted based on the analysis for the water treated and practical experience

with fouling. The FreshPoint™ will automatically initiate a flush if 24 hours (for each 1 day of the Day Override

setting) has elapsed since the last flow initiated flush. This setting is adjusted in the day override setting in master

programming.

A post-ultrafilter pressure tank is recommended to ensure sufficient flow and pressure to the home during a flush

cycle. The backflush surge tank (where installed) will perform the same function.

Refer to Table 1 below for initial set up.

Table 1: Initial Recommended Flushing Parameters by Water Source and Treatment

Water Source

Typical Water Quality to Filter

(with recommended pretreatment)

Recommended

Pretreatment

1

Backflush Kit

Flush Frequency

(Gallons

Throughput)

Flush

Duration

(Seconds)

Surface Water

(Municipally Treated)

• Chlorine < 4.0 mg/l

• Turbidity < 1.0 NTU

• TOC < 2.0 mg/L

• SDI15 < 6.67

• Metals (Fe, Mn, Cu, etc.) < 1 mg/l

• 200 micron prefilter

Recommended

100

30

Surface Water (Private

Multi Barrier Treatment)

• Chlorine > 2mg/l, < 4.0 mg/l

• Turbidity < 5.0 NTU

• TOC < 10.0 mg/L

• SDI5 < 20

• Metals (Fe, Mn, Cu, etc.) < 1 mg/l

• In-Line coagulation and

filtration with multimedia

filter

• Disinfection with chlorine

• 200 micron prefilter

Recommended

50

60

Well (Municipally

Treated)

2

• Chlorine < 4.0 mg/l

• Turbidity < 1.0 NTU

• TOC < 2.0 mg/L

• SDI15 < 6.67

• Metals (Fe, Mn, Cu, etc.) < 1 mg/l

• Iron removal filtration

(if iron over 1 mg/l)

• 200 micron prefilter

Recommended with

high turbidity,

suspended solids,

colloids, or ferric iron

200

30

Well (Private)

2

• Chlorine < 4.0 mg/l

• Turbidity < 1.0 NTU

• TOC < 2.0 mg/L

• SDI15 < 6.67

• Metals (Fe, Mn, Cu, etc.) < 1 mg/l

• Iron removal filtration

(if iron over 1 mg/l)

• Disinfection – optional

• 200 micron prefilter

Recommended with

high turbidity,

suspended solids,

colloids, or ferric iron

100

30

1

In all cases, a disposable pre-filter cartridge is recommended to protect the FreshPoint™ from large particles,

plumbing debris, etc.

2

Some shallow wells may have serious contamination problems, hazy water, high TOC, color and high bacterial

loads. The backflush kit is recommended to avoid fouling in these installations.

NOTE: It is important to understand the water quality and fouling potential to determine the type of

flushing required when installing the FreshPoint™.

Flow Capacity

Assess the household water use, especially peak water draw. The standard single-element FreshPoint™ is

sized for 10 gpm peak capacity flow. Water draw in the house that exceeds peak capacity will have the effect

of reduced pressure and volume delivery at the open taps.
Maximum recommended continuous flow for the FreshPoint™ system is 1.2 gpm for surface water, and 2.9

gpm for well water.

Advertising