Clear-Com Production-Maestro-Pro User Manual

Page 51

Advertising
background image




To add an audio meter to a four-wire on the canvas (pre-populated Port Viewer):

1. In Configure Canvas > four-wire tab, add the four-wire [ ] to the canvas.

2. Select the Other tab. The meter control [ ] is displayed in the list of available

items.

3. To add an input meter, drag the meter control [ ] to the left-hand side of the

pre-populated Port Viewer.

The meter is displayed on the left-hand side of the viewer:


Figure 12: Pre-populated Port Viewer with input meter

4. To add an output meter, drag the meter control [ ] to the right-hand side of

the pre-populated Port Viewer.

The meter is displayed on the right-hand side of the viewer:


Figure 13: Pre-populated Port Viewer with output meter

Note:

You cannot perform output level metering on ports that are not on the same system as the
LMC-64 card.

If you are performing cross-system metering in a fiber-linked Eclipse system (the port being
metered and the LMC-64 card are in different matrices), Clear-Com recommends placing the
LMC-64 card in the matrix where most metering is likely
to occur.

51

Eclipse Production Maestro Pro User Guide

Advertising