Adding channel titles to the display screen, Dding, Hannel – CTI Products RCD Standard - Remote Comparator Display User Manual
Page 35: Itles to the, Isplay, Creen
MCN Remote Comparator Display
Configuring a System
CTI Products, Inc.
Using MCNCFG
68-10856-210
29
using the Edit HIB Address command. Figure 16 shows the dialog box that
appears.
Figure 16 - HIB Address Entry Dialog Box
To enter a new address for the HIB or PCLTA, do the following:
1.
For the Group number, enter a number between 00 and FE (hex). The
default Group number is 80 (hex).
2.
T
over to the Module number field and enter a number between 0 and
F (hex).
3.
T
over to the <OK> button and press
E
to save the new address.
Every screen file must have the correct HIB or PCLTA address programmed.
All MCN modules in a system must have its own unique address. Each
MCNRCD screen files on a single PC should have the same unit address assigned
to them and all PCs should be assigned to a unique unit address. When assigning
addresses to the modules, you may want to reserve a single MCN Group (or
cluster of Groups if you have more than 16 HIBs and PCLTAs in the system) for
all of the HIBs and PCLTAs. Typically, Group numbers 80 and up are used for
HIBs and PCLTAs.
6.5.5 Adding Channel Titles to the Display Screen
If you display multiple channels on a screen, you will probably want to add
channel titles to help the user identify the receivers. Channel Titles can be 18-
characters long.