Sub-categories, Categories, 2 sub-categories – CTI Products RCD Standard - Remote Comparator Display User Manual

Page 96

Advertising
background image

MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

90

9.12.2 Sub-categories

It is possible to connect different types of I/O devices to a single MCN I/O module
(such as a CIB or IOB). This is done by creating sub-categories within a single
category in the MCNRCD.CFG file. To create a sub-category you need to
reserve one or more of the input status signals that make up the input value for the
sub-category selector. The binary combinations of the sub-category selector bits
define the sub-category number. If the input status signal is floating, the sub-
category selector bit is a logic zero. If the input status signal is tied to ground, the
sub-category selector bit is a logic one.

0102
; Display text for MCNRCD
;
; Format:
; state #, hex input, color video, b/w video, log, display position, sound time, sound freq.,
; audio, output, "text"
;
; Comparator Display Category
[DEFAULT]
VOTE=M
DISABLE=L
00 00 1F 0F 0 04 00 0000 00000 0 00 " "
01 01 2F 70 0 04 00 0000 00000 0 00 "Vote"
01 05 2F 70 0 04 00 0000 00000 0 00 "Vote"
02 04 70 70 0 04 00 0000 00000 0 00 "Dis"
03 14 E0 70 1 04 00 0000 00000 0 00 "Dis"
03 50 E0 70 1 04 00 0000 00000 0 00 "Dis"
03 54 E0 70 1 04 00 0000 00000 0 00 "Dis"
04 40 4F F0 1 04 00 0000 00000 0 00 "Fail"
04 44 4F F0 1 04 00 0000 00000 0 00 "Fail"
05 00 6E 70 1 04 00 0000 00000 0 00 "Err"

;
; Alarm and Control Category

Advertising