Locking Out the Front Panel Controls

From the overview screen press the knob to enter the

Top Menu and select LockSet. Rotate the knob either

direction to select LOCKED or UNLOCKED.

When the settings are LOCKED no changes can be

made to the configuration. If an attempt is made to

change a setting, the LCD will flash a reminder that the

settings are locked.

Selecting the Noise Reduction Mode

Two different DSP-based noise reduction modes are

available:

1. Access the SmartNR Setup Screen.

2. Select Receiver Module and rotate the knob to the

desired setting - NORMAL, FULL or OFF.

Selected Receiver

Selected Receiver

SmartNR Mode

is Highlighted

The NORMAL mode is the factory default. It removes

subtle high frequency audio noise but does not affect

the modulated audio in the signal. In the FULL mode,

high frequency audio noise is supressed more aggres­

sively, including noise in the local environment. OFF

applies no noise reduction to the signal.

Listen to the audio signal as you rotate the knob and

select the mode that best fits the situation.

Note: If the selected Receiver Module is part of

a ratio or frequency diversity pair, then setting

the audio output level for one receiver in the pair

automatically sets the other receiver in the pair to

the same setting.

Walk Test the System

Turn everything on and walk each transmitter through

the area where it will be used to check for reliable RF

coverage and audio quality. The control panel GUI has a

convenient Walk Test Recorder which is very helpful in

doing this. Refer to the help file in the supplied software.