Walk test recorder, Factory defaults, Delete vr – Lectrosonics Venue 3.9 User Manual

Page 19

Advertising
background image

Digital Hybrid Wireless™ Modular Receiver System

Receivers 1&2 in Ratio Diversity Mode, Rest in

Switched Diversity Mode

Receiver Module

Frequency Locations

Cursor Select

Walk Test Recorder

The Walk Test Recorder offers a convenient method of

testing the operation of the selected receiver module (or

receiver module pair) with their corresponding transmit­

ters. The Walk Test Recorder makes a chart recording

of the RF signal strength aligned with an audio record­

ing of the receiver modules output.

Use the MC65 cable (supplied with unit) to connect the

PHONES jack output on the Venue Receiver front panel

to the computer system’s audio input.

Record Button

Stop Button

Click the Record button to start the Walk Test Recorder

and the Stop button to stop the recording process. It is

suggested to mention locations frequently during this

test to more easily identify problem areas.

Factory Defaults

Clicking this menu item restores the selected Venue

System to the factory default settings.

The Factory Default Settings are:

Under SetUpRx

Level

+00 dBu

Phase

NORMAL

TxBatt

9V ALK

SmartNR

NORMAL

PilotBP

NORMAL

Compat

Digital Hybrid

Tuning

NORMAL MODE

DivMode

Switched

Under LockSet

Lockset

NOT LOCKED

Delete VR

Clicking the Delete VR menu item deletes the current

Venue System from the VRpanel.