Electrical system – Diamond Products CC6566 User Manual

Page 28

Advertising
background image

Figure 35: Battery and Brace


2. Remove the negative battery boot and

disconnect the negative battery cable lead from
the negative battery terminal.

3. Remove the positive battery boot and

disconnect the positive battery cable lead from
the positive battery terminal.

4. Slide the battery off the battery platform,

keeping it level.

5. When replacing the battery, place a new battery

onto the battery platform, keeping it level. Bring
the old battery to a recycling facility; many
battery retailers also accept old batteries.

6. When cleaning the battery, inspect its terminals,

clamps, and cables for damages and corrosion.
Clean the terminals and clamps using a wire
brush, or use another approved technique for
cleaning. Use acid-free, acid-resistant grease to
grease the battery clamps and terminals.

7. Reconnect the positive battery cable lead to the

positive battery terminal and replace the battery
boot.

8. Reconnect the negative battery cable lead to

the negative battery terminal and replace the
battery boot.

9. Fit the battery support brace over the battery

and retighten the nuts to secure the brace.

Electrical System

WARNING

 DO NOT perform

maintenance on the electrical
system without first
disconnecting the battery.

Always use the correct size fuses (amps)
to prevent fires.

The fuse panel is located behind the switch plate.
Replace fuses as necessary. The Factory Fuses
used are equipped with LED’s; therefore, when the
fuse “blows” it will glow.

Figure 36: Fuse Panel


The relay switches and circuit breaker are located
behind the gauge panel. The circuit breaker should
reset itself during an overload. If the breaker
continually turns on and off, disconnect the battery
to determine the cause of the overload.

Figure 37: Circuit Breaker

28