PROGRAMMING

Step 2

Enter function code 00, then #, the display will show

Step 3

Enter a new 4-digit master code the press #, the display will show

or press * to cancel, the display will show

Disregard the message and the current master code will remain
in the system.

Step 4

Select another function code to continue programming or press *
to exit programming mode and you will hear “three short beeps”.

01

ADD A NEW TENANT

Consists of four fields:

Dir
Directory code, can be set to 2,3 and 4-digit
(use function code 09). Directory code is a
unique number assigned to each tenant, for
example a unit number.

Name
Maximum 16-characters long. For example: Apt
101, ADAM Apt 101, etc. Warning: If the phone
number and access code are programmed
without a name field, the directory code cannot
be edited or deleted unless if you
• Remember the directory code
• Use function code 50 to delete a whole

memory or

• Use software to delete a particular directory

code or view a directory.

Phone Number
Maximum 11-digit long

Access code
4-digit access code (entry code) is used to enter
the building via a system keypad. If you decided
to use the same 4-digit code for all tenants, you
only need to program the access code into one
directory.

Step 1

Log on to programming mode, see instruction above. The display
will show

Step 2

Enter function code 01 then #, the display will show

Step 3

Enter the directory code (see function code 09 for directory digit
setting, default setting is 3-digit). The display will show

Then it goes blank for one second, then it will show

Proceed to step 4.

If the directory code has already used, the display will show

Return to step 2. If the memory is full the display will show

no more tenant can be added, you must delete some of the
unused tenant directory code.

Step 4

Enter a tenant name (up to 16 characters) using the keypad.
Refer to keypad layout diagram.

• Press 0 for space
• Press 8 then 0 for back space
• Press

* to clear all letters or numbers entered or to reset

the keypad’s letters if the letters are out of sequence.

For example: to enter PACH 12

• Press 7 once for letter P then press #

Pach and Company

Chapter 3

Page 8

AeGIS 8000 Series

PROGRAMMING

Master Code: 0000

Select Func: _ _

ERROR DATA

* * * *

Select Func: _ _

Enter Dir: _ _ _

Enter the Name:

_

Dir # is used !

ERROR DATA

* * * *