Chapter 5 trouble shooting guide – Pach and Company AeGIS 7000 Series Manual User Manual

Page 28

Advertising
background image

Chapter 5
TROUBLE SHOOTING GUIDE

NO AUDIO WHEN
KEY(S) IS PRESSED

NO DIAL TONE WHEN
THE # KEY IS PRESSED

THE VISITOR CAN'T
HEAR THE TENANT
FROM THE SYSTEM
BUT THE TENANT CAN
HEAR THE VISITOR

THE TENANT CAN'T
HEAR THE VISITOR
TALKING BUT THE
VISITOR CAN HEAR
THE TENANT

THE LIQUID CRYSTAL
DISPLAY (LCD) SHOWS
QUESTION MARKS
(????)

THE LIQUID CRYSTAL
DISPLAY (LCD) IS
BLANK, NO DISPLAY AT
ALL

• Check the speaker and microphone connection on the board. The snap on

clip connector on the speaker and microphone connector must be facing
inside the board.

• Check the red and orange wires, make sure they are soldered into the

speaker.

• Turn the power "OFF" and disconnect the speaker connector from the board.

Set your meter to Ohm and use 50 Ohm scale or higher. Put the two probes
into the speaker (+) and (-) (polarity not important) and the meter should read
between 19 - 24 Ohms.

• Check the phone line using a standard phone, make sure you get dial

tone.

• Check the speaker and microphone connection. The snap on clip connector

on the speaker and microphone connector must be facing inside the board.

• Check the red and orange wires, make sure they are soldered into the

speaker.

• Turn the system's power "OFF" and disconnect the speaker connector from

the board. Set your meter to Ohm and use 50 Ohm scale or higher. Put the
two probes into the speaker (+) and (-) (polarity not important) and the meter
should read between 19 - 24 Ohms.

• Check the speaker and microphone connection. The snap on clip connector

on the speaker and microphone connector must be facing inside the board.

• Check the red and orange wires, make sure they are soldered into the

speaker.

• Press the # key as soon as you hear a dial tone, tap your finger into the

microphone and you should hear a finger tap sound from the speaker.

• Check the speaker and microphone connection. The snap on clip connector

on the speaker and microphone connector must be facing inside the board.

• Check the brown and black wires, make sure they are soldered into the

microphone.

• Turn the system's power "OFF" and disconnect the speaker connector from

the board. Set your meter to Ohm and use 50 Ohm scale or higher.
Put the two probes into the speaker (+) and (-) (polarity not important) and the
meter should should read between 19 - 24 Ohms.

• Turn the unit power "OFF" and "ON".
• Erase the memory chip (EEPROM) using Function Code 50. If you have

trouble to log on to programming mode, press and release the square red
button then press #.

• The power LED must be "ON" (LED2 marked on the board).
• The Power Switch's toggle must be on the left position ("ON").
• Check the fuse (3 Amp 250 Volt).
• Measure the voltage on AC1 and AC2 (set your voltmeter to AC and put the

probes on AC1 and AC2), it should read within 12VAC-13.8VAC or if you use
12 VDC, the meter must read 13.5 - 14.0 VDC.

• The LCD's ribbon cable has red dots along the side. The red dots must be

facing up. It must be connected to the terminal marked number 1.

Pach and Company

Chapter 5

Page 21

AeGIS 7000 Series

TROUBLE SHOOTING GUIDE

AUDIO PROBLEM S

SOLUTIONS AND SUGGESTIONS

DISPLAY PROBLEM S

SOLUTIONS AND SUGGESTIONS

Advertising