GETTING STARTED

1.1 Introduction

Pach & Company thanks and congratulates you on the purchase of your AeGIS 7000 Series (7025, 7050, 7100, 7150,7200
or 7250) Telephone Access Control Systems.

The manual is designed to guide you through the proper programming and use of the AeGIS 7000 Series. It is important for
you to read and follow the manual completely.

The Aegis 7000 Series comes with two years warranty, see section 1.4 for more detail on warranty policy.

1.2 System Description, Specifications and Accessories

AeGIS 7000 Series utilizes microprocessor technology to provide security as well as convenience to you. It is designed for
residential and commercial buildings, military and government sites, industrial facilities, or any location where access control
is required. It uses a dedicated phone line and connects to the public telephone network. Authorization for access control is
through the telephone line, or with the tenant's own access code, which is entered on the system keypad. The tenants MUST
have a telephone to allow remote visitor access.

Also, as a standard feature, the tenant is allowed to "call" the Aegis unit and converse with the visitor and "remote
programming" using a touch tone phone.

The system parameters and tenants data will be entered via the keypad and the LCD provides easy display. EEPROM
technology is used for AeGIS 7000 series. The tenant database will not be lost during a power failure.

Standard features:

• Program and store the tenant's name, directory code, telephone number and personal access code.
• Unlocking door or gate remotely by the tenant using his or her telephone keypad.
• Unlocking door or gate by the tenant using his or her own private access code.
• Built-in back-light LCD directory, Postal Switch.
• Works behind a PBX to dial extensions (analog only).
• Keypad Activated to support Voice Mail.
• Programmable features:

• 2, 3 or 4 Digit Directory Code
• Lock Out Count
• Manual Unlock-Auto Countdown Re-lock.
• 4 Digit Unit master Code
• Open Interval
• Talk Time

Technical Specifications:

Power Input: 12 VAC 40 VA (supplied) or 12 VDC 40VA UL Listed Transformer

Current Consumption: 500mA idle, 700mA operation

Emergency Battery: 12Vdc, 4Ahr rechargeable (not supplied)

Telephone Line: Standard voice grade RJ11 jack.

Night Light: 14V 0.080A 15,000 Average life hours.

Operating Environment: Temp. 32°F to +140°F Relative Humidity 0% to 95% non-condensing.

* Heater Pad (AHP5) is required if the ambient temperature is below 32°F.