Operation Modes

General Modes of Operation

In each mode of operation, the user may press keypads
or communicate with the control to change the
displayed menu.

Power-up Mode

The control enters this mode at power-up. After the
control completes operation in the Power-up Mode it
will enter Idle Mode. The display is blank during
Power-up Mode.

Idle Mode

Control is ready for operation in Idle Mode. Control
can display different menus depending on user input
(keypad press, opening or closing the loading door, or
PDA communication). If there is no user input for one
minute, control will turn off the LCD backlight.
Control will light when there is user input. If there is
no user input for 10 minutes, display will go blank.

If control is in Idle Mode, Cycle Menu is displayed,

loading door closed, and the

keypad is pressed,

control will enter Run Mode.

Run Mode

Control enters Run Mode during a cycle

.

Display

shows machine cycle time remaining, the colon
flashing one second on/one second off indicating that
the cycle time is counting down, and the display will
indicate the current cycle step. Loading door is closed

and locked during Run Mode. Press

keypad to

end cycle and enter Stop Mode. Press

keypad to

Rapid Advance to the next cycle step (if the Rapid
Advance feature is enabled. The Rapid Advance
feature is enabled by default.) Control enters Error
Mode if loading door unlocks or opens.

Stop Mode

If

keypad is pressed before cycle ends, control

enters Stop Mode and performs the following steps:

• Displays a hourglass.
• Turns off all outputs.
• Verifies water is drained.
• Verifies motor is stopped by either rotation

sensor or time.

• The control will display the unlock door screen.

The user must unlock and open the door to return
to the Cycle Menu.

Error Mode

This mode will be entered to display all alarms and
machine errors.

Delayed Start Countdown Mode

Delayed Start Countdown Menu is entered after
delayed start is activated. The display will show the
hours and minutes remaining until the machine will
automatically start.

The Delayed Start Final Countdown Menu is entered
during the last sixty seconds before the control is

automatically started. The

keypad will start the

selected cycle immediately. Press

to return to the

Cycle Menu.

Communication Mode

This mode is entered whenever the control is
communicating with a PDA. Refer to UniLinc PC and
PDA Applications User Instructions.

Entering Diagnostic Mode From Idle Mode

When entered from the Idle Mode, the control will be
running a test selected by the user via keypad presses
or communication with a device. The diagnostic tests
available from the Idle Mode are the Test Cycle, Test
Balance Weight, and Inputs Outputs Menus.

Advertising