Heater option supply a and b step menu, M m : s s – Alliance Laundry Systems PHM1401C User Manual

Page 37

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Program Menu

35

F8138801

The next parameter controls the heater while the
machine is actually in the Agitate Step. This parameter
is only displayed if a heater is present.

There are three choices on heater equipped machines.
The choices are “No Heat”, “To Target”, and
“Maintain”. If “No Heat” is selected, the heater will
not function during the Agitate Step. If “To Target” is
enabled, the heater will turn on in the Agitate Step and
reach the desired water temperature. Once the desired
water temperature is reached the heater shuts off. If
“Maintain” is selected, the heater is turned on and off
as necessary throughout the Agitate Step to maintain
the desired water temperature.

The time that is programmed refers to the Fill Alarm
Time. If the time is set to the global Fill Alarm Time, a
“g” will be displayed to the left of the time. The time
can be changed to a specific value for an individual

cycle by entering Time Edit Mode, using

and

keypads to navigate between minutes and

seconds, and

and

keypads to change the

time. The Fill Alarm Time is the amount of time
allowed for fill to complete. If fill is not reached by
Fill Alarm Time, the control will enter Error Mode.

The Reuse Fill Step and Fill Step cannot both be
enabled in the same segment. If the Reuse Fill Step is
enabled then the Fill Step will be turned off.

Press the

keypad to enter the Save Changes

Menu.

Heater Option

If a Heater is present it can be programmed to heat
water during an Agitate cycle step. The Fill step of a
cycle segment contains the Heater programming
options for that segment. If the Heater is programmed
to On in the Fill step of a segment, the Heater is turned
on during the Agitate cycle step in order to heat the
water to the target temperature specified by the
programming information of the segment’s Fill step.

The target temperature can be programmed for the
segment in one of two ways. The Fill Step can be
programmed to use the Hot, Warm or Cold Global
temperature value. The Fill step can also be
programmed to a water temperature specific to this
segment. During the initial heater on time, the
remaining cycle time count-down will pause until the
target temperature is reached. If the heater is turned on
for more than the Global Heater Alarm time and the
desired temperature is not reached, the heater is turned
off and the Cycle Stopped Error Menu is displayed
prompting for user input. The Heater Error is logged

.

The user may either abort or continue the cycle. If the

Fill Step for this segment is programmed to maintain
the heated water temperature, the heater will be turned
back on in the Agitate step any time the water
temperature has fallen more than five (5) degrees F
below the programmed target temperature. If the water
level ever falls below the programmed water level, the
heater will be turned off until the programmed water
level is reached again.

Supply A and B Step Menu

The Supply A and Supply B Step Menus are used to
control which supply or supplies that are activated
during a Segment and the duration of the dispensing.
The Internal Supplies are listed from S1 to S5 and
external supplies are numbered ES1 through ES8. Any
of the internal, external, or both type of supplies can
be turned on or off during Supply Step A or Supply
Step B. Any combination of SUPPLIES is possible in
both menus.

PHM1027R

Figure 30

PHM1028R

Figure 31

Modify Cycle

Cycle01: Towels White Bleach
Segment01: Prewash

Supply A:

Internal

External

m m : s s

Time

E S I

E S 2
E S 3
E S 4

E S 5
E S 6
E S 7
E S 8

S 3 S 4 S 5

S I S 2

Modify Cycle

Cycle01: Towels White Bleach
Segment01: Prewash

Supply B:

Internal

External

m m : s s

Time

E S 2

E S 4

E S 5

E S 7

S 4 S 5

S I S 2 S 3

E S I

E S 3

E S 6

E S 8

Advertising