Agitate step menu cool down step menu, M m : s s – Alliance Laundry Systems PHM1401C User Manual

Page 38

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Program Menu

F8138801

36

The

and

keypads are used to move the

cursor to the different parameters and Internal

Supplies 1 through 5. The

and

keypads

are used to move the cursor to the External Supplies 1
through 8.

Once a supply has been chosen, it is

selected by pressing the

keypad. The supply is

activated if it is highlighted. The time can be edited for
each supply step by moving the highlighter box to

time. Press

. Blinking underline indicates the

number is ready to be changed.

Pressing the

keypad will jump to the Save

Changes Menu.

Agitate Step Menu

The purpose of the Agitate Step Menu is to program
the parameters used while the machine is performing
the Agitate Step. The Agitate cycle step can be turned
on or off. The type of agitation is the first available
parameter. The agitation type parameter menu has
seven (7) choices with 18F/3P/18R (18 seconds
forward, 3 seconds pause, and 18 seconds reverse)
being the default.

The recirculation parameter controls the operation of
the recirculation pump during machine operation. The
user can either turn it on or off. If the water
recirculation option is not enabled in Global Setup
parameter, then this parameter will not display. The
Wash speed can be programmed to either Normal
Wash speed or Reduced Wash speed.

The Agitate step can be programmed to a time from
one (1) minute to 30 minutes.

NOTE: If the Agitate type is programmed to a
value of “No Rotation”, the cycle step time can be
programmed to a value from one (1) minute to 24
hours.

Pressing the

keypad will jump to the Save

Changes Menu.

Cool Down Step Menu

The Cool Down Step Menu gives the user the option to
set the Cool Down Option after the Agitation Step.
The Cool Down cycle step can be turned on or off. If
turned off, the control will advance to the next cycle
step (Drain).

The temperature setting allows the user to set the Cool
Down temperature of the water after the Agitation
Step has ended. The temperature will default to cool
down temperature set in Global Setup. To change cool

down temperature, press the

and

keypads.

Press the

keypad to jump to the Save Changes

Menu.

PHM1029R

Figure 32

Modify Cycle

Cycle01: Towels White Bleach
Segment01: Prewash

Agitate:

Type

m m : s s

Time

Speed

Recirc

Reduced

No Rotation

Drain Only

3F/27P/3R

10F/20P/10R

18F/3P/18R

Continuous

Normal

On

Off

4F/56P/4R

PHM1030R

Figure 33

Modify Cycle

Cycle01: Towels White Bleach
Segment01: Prewash

Cooldown:

Temp

GLOBAL

Advertising