Cycle stopped, Speed, temp and water level menu, Cycle aborted retry menu – Alliance Laundry Systems PHM1401C User Manual

Page 26: Cycle01: towels white bleach segment01: wash fill

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Machine Cycle Definition and Operation

F8138801

24

Speed, Temp and Water Level Menu

The Speed, Temp, and Level Menu will display the
actual RPM, temperature and level, and program
values of the temperature and level during run mode.
The top portion of the display contains the same
information listed in the Run Menu detailing Cycle,
Segment, and Step operation.

Press

keypad to enter Run Mode Diagnostic

Menu. Press

keypad to stop the cycle, the

control will enter Cycle Stopped if there is rotation or
the Unlock Door page if there is not rotation. Press the

keypad to advance the cycle one step. The

Control cannot advance into a Spray Rinse Extract or
an Extract Cycle Step. Advancing the steps within a
cycle also depends on whether this option has been
changed to on or off in the Rapid Advance Menu.

Cycle Aborted Retry Menu

The Cycle Aborted Retry Menu will be displayed for a
fill, drain or heater alarm time error. The display will
toggle this page with the Run Menu every three

seconds. Press

to resume the cycle.

PHM1083R

1

Cycle Name

7

Programmed Water Temperature

2

Segment Name

8

Actual Water Level

3

Step Name

9

Programmed Water Level

4

Segment Time Elapsed

10

Actual RPM

5

Step Time Remaining

11

Run Screen Indicator

6

Actual Water Temperature

12

Cycle Time Remaining

Figure 13

Cycle01: Towels White Bleach
Segment01: Wash
Fill

Actual

Temp

138 F

140 F

Program

01:42
01:42

Run Menu

PHM1083R

Level

01

01

RPM

40

9

7

11

3

1

6

2

5

8

10

4

12

PHM1011R

Figure 14

Cycle Stopped

Heater Alarm Time Exceeded

Press START Key to Retry

Press STOP Key to Abort Cycle