Diagnostic

F8138801

52

Inputs Outputs Menu

When the Inputs Outputs Menu is accessed through
the Diagnostic Menu, the user can change outputs. The
Close Door Menu will come up if the door is not
closed. The user can scroll through the outputs using
any of the arrow keys, the cursor is indicated by
flashing the active output on the screen. The user must

“setup” the outputs to be turned on. The

keypad

is used to toggle individual outputs to be turned on or

off. After the

keypad is pressed the control will

turn the selected outputs on and display the text
“RUNNING”. The outputs cannot be toggled until

the

keypad is pressed. The text “RUNNING” is

no longer displayed. The screen will still show the
selected outputs on the screen and the user can again

toggle outputs to be turned on or off. If the

keypad is pressed at any time during this test, the
control will turn off all outputs if the test is running or
return to the previous screen if the test is not running.

PHM1059R

Figure 65

Inputs Outputs

Outputs:

Inputs:

RUNNING

S1

S2

S3

S4

AX1 HF

CF

FW

RV

HS

CS

RFA RFB RDB AX3 AX5

DR

AX4

AX2 ES1 ES2 ES3 ES4 ES5 ES6 ES7 ES8

DR

BAL PAUS DFLT FSW WL

RS

TS

DL

SP1 ON

HT RUN REV

OSW PSW

SPD1 SPD2 SPD3

Advertising