Alliance Laundry Systems PHM1401C User Manual

Page 52

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Diagnostic

F8138801

50

* Step is skipped if no heater in machine.

Table 4 (Continued)

STEP

Test Cycle Step

Displayed Description

STEP ADVANCE

COMMENTS

22

Int Supply #3
Wash Speed Agitate

“Internal Supply #3”

Keypress
or 30 seconds

23

Internal Supply #4
Wash Speed Agitate

“Internal Supply #4”

Keypress
or 30 seconds

24

Warm Fill to Overflow
Reduced Wash Speed
Agitate

“Cold Fill To Overflow”

Keypress

25

(*1)

Heat water to 110F
Reduced Wash Speed
Agitate

“Heat Water to 110F”

Keypress

All outputs turned off when
temperature reached.

26

Reduced Wash Speed
Forward with no agitation
action.

“Reduced Wash Speed”

Keypress

27

Wash Speed Forward
with no agitation action.

“Wash Speed Forward”

Keypress

28

Wash Speed Reverse with
no agitation action.

“Wash Speed Reverse”

Keypress

29

Drain
Distribution Speed

“Drain”

Keypress when empty

30

Extract Speed #1
“very low”

“Extract Speed 1”

Keypress

31

Extract Speed #2
“low”

“Extract Speed 2”

Keypress

32

Extract Speed #3
“medium”

“Extract Speed 3”

Keypress

33

Extract Speed #4
“high”

“Extract Speed 4”

Keypress

34

Extract Speed #5
“very high”

“Extract Speed 5”

Keypress

35

(*3)

Audio Signal

“Audio Signal”

Keypress
or 5 seconds

Step skipped if Global
Audio Signal and Global
External Signal is disabled.

36

Coast Time

“Coast”

Table 4

Advertising