Access Location

E-Mon Energy User Manual

14-8

E-MON

Verify Meters Button

The Verify Meter tells us the condition and if the services are functioning properly. If a meter configuration

mismatch occurs, a warning will display in this window. The illustration below shows that the Meters are

functioning properly.

Figure 14.13 - Access Location Function – Verify Meters

Columns

Description

Status

This column displays the condition of the device. If the condition

states “Bad” or “Timeout,” there is a possible error in reading the

device and there may be a hardware or communication issue. If the

condition is “ok,” the hardware is functioning normally.

ID

This column displays the meter ID number.

Volt

This column displays the rated voltage setting.

Amp

This column displays the rated amperage setting.

CTs

This column displays the number of sets of current sensors.

Pulse

This column displays the pulse input type setting (i.e. 50/50, Run-

hour, Analog).

Mfg (manufacture)

This column displays the manufacture name of the meter.

Type

This column displays the type of service of the meter (i.e. Electric,

Gas).

Mult (Multiplier)

This column displays the meter multiplier.

Pul (Pulse) Factor

This column displays the meter pulse factor setting.

CT/PT

This column displays the “current transformer” and “potential

transformer” setting.

Warnings

This column displays any alarms and/or configuration mismatch

with the meter. Note: E-Mon Energy™ compares settings

programmed into the meter with settings stored in the database.

They should be identical.