Data Output Example
The example below shows the format of the COM1 output connected to a
printer. Actual data output format may vary depending on the configuration
and set-up of this port using the AFC User Console Software. The data field
is selectable from all the available output fields to as little as one output field.
(See previous table for available data fields) Headers, Footers & ASCII
control characters are all configurable using the AFC User Console Software.

2002/09/26 09:17:57 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG

Acceptable Fastening

01 01 0.50 2 0.000 0.005 0.00 O

2002/09/26 09:19:36 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG

Rejected Fastening

01 01 0.17L 0 0.000 0.000 0.00 X

2002/09/26 09:21:16 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG

Reset Cycle

01 01 0.23L 0 0.000 0.000 0.00 !

(Before fastening end)

2002/09/26 09:21:21 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG

Cycle Stopped

01 01 0.17L 0 0.000 0.000 0.00 !

(Before fastening end)

2002/09/26 09:21:34 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG

Abnormal

01 01 0.01 0 0.000 0.000 0.00 A05

(Showing abnormal code)

2002/09/26 09:21:21 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG

Spindle Bypassed

01 00 0. 0.

0. 0. 0.

Index
SEQ: Sequence

1RATE: 1st Rate

H: High

SP: Spindle

2RATE: 2nd Rate

L: Low

PA: Parameter

OFSET: Offset Torque

ANGLE: Final Angle

JUG: Judgment