Interface adapter installed – FEC AFC1500 User Manual
Page 27
SW1 DIP Switch setting for I/O board selection
M-Net
ON
ON
ON
ON
-15
CCLink* (Switches 5-8 NOT USED)
ON
ON
ON
OFF
-14
Profibus - S
ON
ON
OFF
ON
-13
Reserved
ON
ON
OFF
OFF
-12
Interbus S - S
ON
OFF
ON
ON
-11
Reserved
ON
OFF
ON
OFF
-10
Devicenet - S
ON
OFF
OFF
ON
-9
Reserved
ON
OFF
OFF
OFF
-8
Profibus - DT
OFF
ON
ON
ON
-7
Allen Bradley Remote I/O
OFF
ON
ON
OFF
-6
Interbus S - DT
OFF
ON
OFF
ON
-5
DeviceNet(Estop) - DT
OFF
ON
OFF
OFF
-4
DeviceNet - DT
OFF
OFF
ON
ON
-3
24VDC Source Discrete I/O
OFF
OFF
ON
OFF
-2
24VDC Sink Discrete I/O
OFF
OFF
OFF
ON
-1
INTERFACE TYPE
SW1
4
SW1
3
SW1
2
SW1
1
Part #
Suffix
Part # suffix refers to number added to Multi Unit Part number
(example: 1500Multi - 13 is a Multi unit with a Profibus -S interface board
installed)
-DT & -S boards refer to type of
interface adapter installed.
-DT = Data transfer model(old model)
-S = Serial model (current model)
Devicenet (Estop) version is without Estop signal control
Chapter 3:
Control Interfaces
27