Typical I/O Layout (Fieldbus)
The following I/O layout map is provided as a typical reference of the bit
addressing for FIELDBUS systems. This is only a reference and NOT
intended for any particular application or fieldbus type. See your application’s
Electrical Control Schematic drawings for your actual I/O layout.
Note: The inputs are permanently set in the location shown and cannot be
changed. However, the Output locations are programmable and may not
reside in the locations shown.

Inputs

Not Used

96*

Not Used

64

Data Sel. 2 (N/A)

32

Not Used

95

Not Used

63

Data Sel. 1 (N/A)

31

Not Used

94

Not Used

62

Data Sel. 0 (N/A)

30

Not Used

93

Not Used

61

Not Used

29

Not Used

92

Not Used

60

Not Used

28

Not Used

91

Not Used

59

Not Used

27

Not Used

90

Not Used

58

Spindle Bypass 10

26

Not Used

89

Not Used

57

Spindle Bypass 9

25

Not Used

88

Not Used

56

Spindle Bypass 8

24

Not Used

87

Not Used

55

Spindle Bypass 7

23

Not Used

86

Not Used

54

Spindle Bypass 6

22

Not Used

85

Spindle Bypass 31

53

Spindle Bypass 5

21

Not Used

84

Spindle Bypass 30

52

Spindle Bypass 4

20

Not Used

83

Spindle Bypass 29

51

Spindle Bypass 3

19

Not Used

82

Spindle Bypass 28

50

Spindle Bypass 2

18

Not Used

81

Spindle Bypass 27

49

Spindle Bypass 1

17

Not Used

80

Spindle Bypass 26

48

Input Port 3

16

Not Used

79

Spindle Bypass 25

47

Input Port 2

15

Not Used

78

Spindle Bypass 24

46

Input Port 1

14

Not Used

77

Spindle Bypass 23

45

Input Port 0

13

Not Used

76

Spindle Bypass 22

44

Not Used

12

Not Used

75

Spindle Bypass 21

43

Not Used

11

Not Used

74

Spindle Bypass 20

42

Cyc. Count Reset

10

Not Used

73

Spindle Bypass 19

41

Cycle Count - Up

9

Not Used

72

Spindle Bypass 18

40

Seq. Select 3

8

Not Used

71

Spindle Bypass 17

39

Seq. Select 2

7

Not Used

70

Spindle Bypass 16

38

Seq. Select 1

6

Not Used

69

Spindle Bypass 15

37

Seq. Select 0

5

Not Used

68

Spindle Bypass 14

36

Start

4

Not Used

67

Spindle Bypass 13

35

Reverse

3

Not Used

66

Spindle Bypass 12

34

Reset

2

Not Used

65

Spindle Bypass 11

33

Stop

1

Input

Bit

Input

Bit

Input

Bit

*Note: The number of data bits reserved for inputs varies with the type of
fieldbus interface. It varies between 16 & 256 (or more), even though the
number of inputs are limited to this list. See your applications Electrical
Drawings for this information.

Chapter 4: I/O and Output Data