Fieldbus i/o assignment – FEC AFC1500 User Manual
Page 49

Address 59
ON
ON
ON
OFF
ON
ON
Address 58
ON
ON
ON
OFF
ON
OFF
Address 57
ON
ON
ON
OFF
OFF
ON
.
.
.
.
.
.
.
Address 3
OFF
OFF
OFF
OFF
ON
ON
Address 2
OFF
OFF
OFF
OFF
ON
OFF
Address 1
OFF
OFF
OFF
OFF
OFF
ON
Address 0*
OFF
OFF
OFF
OFF
OFF
OFF
MAC ID
SW-8
SW-7
SW-6
SW-5
SW-4
SW-3
(LSB)
Address setting (DIP switch)
This switch must be set before power is on, and cannot be changed during
operation.
*Address should be set to “0” if this is the only device on the network.
Reserved
ON
ON
230K
ON
OFF
115K
OFF
ON
57.6K
OFF
OFF
Baud rate
SW-2
SW-1
Baud rate setting (Board switch)
Baud rate must match the settings of the Remote I/O scanner.
This switch must be set before power is on, and cannot be changed during
operation.
Fieldbus I/O Assignment
See Input/Output Signal & Fastening Data Outline Section (4) for a
description of the I/O and it’s assignment location.
Chapter 3:
Control Interfaces
49