FEC AFC1500 User Manual

Page 55

Advertising
background image

Bypass’s spindle #31 - Spindle is ignored as if it does
not exist.

Bypass Spindle
#31

55*

.

.

.

Bypass’s spindle #11 - Spindle is ignored as if it does
not exist.

Bypass Spindle
#11

35*

Bypass’s spindle #10 - Spindle is ignored as if it does
not exist.

Bypass Spindle
#10

26*

.

.

.

Bypass’s spindle #1 - Spindle is ignored as if it does not
exist.

Bypass Spindle
#1

17*

Data Select 2

32

Data Select 1

31

These lines form a binary code to select up to 8 Output
Data Banks. Used for Digital I/O interfaces. NOTE: Not
Used for Fieldbus interfaces.

Data Select 0

30

Multi Unit Input Signals

* Spindle Bypass signals can only be used with a Fieldbus interface (except
spindle 1-10 is available in discrete I/O) . If using the Discrete I/O interface
the spindle bypass signals are wired from the SAN Unit PLC connector (if you
have more than 10 spindles) . See I/O layout for input location in fieldbus.

Sequence Select Table
Sequences are selected using the Sequence Select Bits 0-3. Using these four
bits in a binary fashion, 16 sequences can be selected. With all bits “OFF”,
sequence #1 is selected and with all bits “ON”, sequence #16 is selected. The
Sequence must be set before the start signal is received. It is recommended
when using multiple sequences that the Sequence Output signals (SEQ. 0-3)
be used to confirm which sequence is selected BEFORE starting the cycle.

on

on

on

on

16

on

on

on

off

15

on

on

off

on

14

on

on

off

off

13

on

off

on

on

12

on

off

on

off

11

on

off

off

on

10

on

off

off

off

9

off

on

on

on

8

off

on

on

off

7

off

on

off

on

6

off

on

off

off

5

off

off

on

on

4

off

off

on

off

3

off

off

off

on

2

off

off

off

off

1

Seq Select 3

Seq Select 2

Seq Select 1

Seq Select 0

Sequence

Chapter 4: I/O and Output Data

55

Advertising