Ransburg – Ransburg REA Automatic Applicators 77359, 76110, 77140 User Manual
Page 11
REA 900 and 9000 Automatic
Applicators 77539 and 76110 ATEX
Product Marking Definitions
Ex Certificate Number: Sira 08ATEX5040X
Sira = Notified Body performing EC-type exam-
ination
08 = Year of certification
ATEX = Reference to ATEX Directive
5 = Protection Concept Code (code 5 is titled
Encapsulation)
040 = Document serial number
X = Special conditions for safe use apply
Special conditions for safe use: The REA 77359
and 76110 Automatic Applicators shall only be
used with associated 76580-XX Control Unit.
Product
Marking
II 2 G
Ex = Specific marking of explosive protection
II = Equipment Group hazardous area characteristics
2 = Equipment Category
G = Type of explosive atmosphere (gases, vapors,
or mists)
EEx 0.24mJ = The REA Automatic Applicators
77359 and 76110 are suitable for use in automatic
spraying installations complying with EN 50 050 as
they are a Type A class with a discharge energy
limit of 0.24mJ.
Label 78974
Label 76858
Label 72562
Label 79648
Ransburg
REA Automatic Applicators - Atex
7
AA-99-02.5