Ransburg – Ransburg REA Automatic Applicators 77359, 76110, 77140 User Manual

Page 22

Advertising
background image

Paint Preparation

A proper paint mixture is essential to electrostatic

operation. Paint test equipment may be obtained

through your Ransburg representative. Consult

Ransburg “Paint Related Information for REA and

REM Applicators” manual, for paint formulation

information. For further paint formu-lation and

testing procedures, consult your Ransburg rep-

resentative and/or your paint supplier.

Spray Technology Conversion

Procedure

Remove existing retaining ring and air cap from

end of applicator. Remove fluid nozzle using

applicator wrench 19749-00.

Atomizer Assembly Selection

The “Atomizer Assembly Selection Chart” is pro-

vided to give you a comparison of the air caps

and fluid nozzles.

THE CHOICE OF ATOMIZER

ASSEMBLY SHOULD DEPEND ON QUALITIES

DESIRED AND MUST BE VERIFIED BY ACTUAL

TRIAL. See your authorized Ransburg electro-

static distributor for atomizer demonstration.

Spray Pattern Adjustment

The spray pattern of fan atomizers is adjustable

from a small circle to an elongated oval, approx-

imately 10 to 18-inches across the usable long

axis at 8 to 12-inches from the target. The swirl

atomizer assemblies produce a round pattern

from 5 to 9-inches in diameter. To adjust pattern

size, increasing fan air pressure will expand the

pattern, a reduction will decrease it. To change

the spray pattern axis of fan atomizers from

horizontal to vertical, loosen retainer ring, rotate

the air cap clockwise to the desired position and

gently tighten the ring.

> To avoid damage to the fluid nozzle and

electrode, the paint pressure and trigger return

spring tension

MUST be released by triggering

the applicator prior to removing the fluid nozzle.

> The applicator

MUST be tilted front down to

remove the fluid nozzle. Failure to do so may

allow paint to enter the air passages, thereby

reducing air flow and damaging the applicator

barrel or cause electrical shorting. Applicators

may be flushed in lieu of tilting, but they

MUST

be either flushed or tilted

BEFORE removing

the fluid nozzle!

C A U T I O N

!

With a bladed screwdriver, remove pressure

reducers by turning counter-clockwise from bar-

rel. Install the desired pressure reducer. Apply

suitable liquid pipe thread sealant to threads.

Install appropriate fluid nozzle, gently tightening

into place using the applicator wrench 19749-00.

Reinstall appropriate air cap and retaining ring.

(See “Nozzle Selection Chart” later in this section,

for proper combination of air caps, fluid nozzles

and pressure reducers).

For remote HVLP fan air applications fan control,

air pressure should not exceed 10 psi. Fan con-

trol pressure should be adjusted depending upon

pattern size desired.

> A counter-clockwise turn of the air cap may

loosen the fluid nozzle and cause air to get

into the paint or paint to cross over into the air

passages.

C A U T I O N

!

Applicator To Target Distance

Mount the applicator 6 to 12-inches maximum

from the target for best operation. (A higher

transfer efficiency will be achieved at the closer

target distance).

Ransburg

REA Automatic Applicators - Installation

18

AA-99-02.5

Advertising