6. Install new connector assembly in rear mounting

plate and secure with screw.

7. Reconnect low voltage cable to connector

assembly using a wrench on connector flats to

tighten.

8. Reinstall mounting plate and applicator to robot.

LOW VOLTAGE CABLE

PLUG ASSEMBLY

(REA 9000R)

1. Remove applicator from robot.

2. Thread screws into threaded hole in plug as-

sembly.

3. Pull on screw to remove plug assembly from

P-extension.

4. Insert female end of new plug assembly into

P-extensions. Push plug assembly in until com-

pletely seated.

NOTE

> It does not matter which receptacle of

the plug assembly is connected to which

pin of the P-extension.

5. Reinstall applicator to robot.

NOTES