VALVE BODY SERVICE

(REA 9000W)

When service is performed on any of the body

elements, it is best to remove the barrel and high

voltage module / transformer assembly to avoid

damage to the nozzle, electrode or any of the

plastic parts.

After the disassembly of any body element:

• Clean all parts with a suitable clean solvent.

• Check all parts for damage or wear. Replace

those that are damaged or worn with new

parts.

AIR VALVE BODY

DISASSEMBLY

(REA 9000W)

1. Remove barrel assembly (see “Barrel Re-

moval for the 9000W”, previously discussed in

this section).

2. Remove high voltage module/transformer

assembly (see “Transformer Assembly Re-

place-ment, for the 9000W”, previously discussed

in this section).

3. Remove two (2) back plate screws.

TO RETURN THE SPRAY

APPLICATOR TO THE

WORK SITE

1. Attach applicator to mounting bar and secure

screws.

2. Attach the air line to applicator air fittings.

3. Attach fluid hose to fluid hose fitting.

4. Attach and secure the low/high voltage cable

to the spray applicator.

5. Turn the power, air and fluid on at the source

and return the applicator to service.

>

DO NOT overtighten low voltage cable con-

nection to spray applicator as damage to plastic

parts may occur.

C A U T I O N

!

Assembly:

1. Connect low voltage cable to control unit;

hand tighten.

2. Connect other end of low voltage cable to con-

nector assembly using a wrench on the connector

flats to tighten.