Ransburg, Transformer assembly replacement, Low voltage cable replacement – Ransburg REA Automatic Applicators 77359, 76110, 77140 User Manual

Page 43: Low voltage cable connector assembly

Advertising
background image

W A R N I N G

!

>

Turn

OFF all power, air, and fluid at the

source.

TRANSFORMER

ASSEMBLY

REPLACEMENT

(REA 9000R AND 900A)

1. Remove the low voltage cable connector from

the transformer by removing the scew and pull

STRAIGHT out of the chamber.

2. Remove the barrel/cascade assembly. (See

“Barrel Assembly Removal” in the “Maintenance”

section.)

3. Remove the fiberglass screw.

4. Slide transformer backward and upward out

of body channel.

C A U T I O N

!

> The low voltage cable

MUST be removed

before removing the transformer assembly.

NOTE

> Generously lubricate transformer

assembly base and body channel with

LSCH0009-00 dielectric grease.

5. Slide replacement transformer into channel of

automatic body.

6. Place gasket in position.

7. Replace the barrel/cascade assembly. (See

“Barrel Assembly Removal in the “Maintenance”

section.)

8. Install low voltage cable connector by matching

the hole on the connector and the transformer, and

pushing the connector

straight into the chamber.

9. Secure in place with screw.

LOW VOLTAGE CABLE

REPLACEMENT

(REA 9000R)

1. Remove applicator from robot.

2. Remove rear mounting plate from fobot.

3. Using a wrench on connector flats, disconnect

low voltage cable from connector assembly.

4. Replace cable in robot arm.

5. Connect new cable to connector assembly

using a wrench on the connector flats to tighten.

C A U T I O N

!

>

DO NOT overtighten low voltage cable

connection to spray applicator, as damage to

plastic parts may occur.

LOW VOLTAGE CABLE

CONNECTOR ASSEMBLY

(REA 9000R)

1. Remove applicator from robot.

2. Remove rear mounting plate from fobot.

3. Using a wrench on connector flats, disconnect

low voltage cable from connector assembly.

4. Remove screw from rear mounting plate.

5. Pull connector assembly out of mounting plate.

Ransburg

REA Automatic Applicators - Maintenance

39

AA-99-02.5

Advertising