SERVICE - REA 9000R AND REA 900A SERIES

BARREL ASSEMBLY

REMOVAL

(REA 9000R & 900A)

C A U T I O N

!

> Firmly spreading the retaining ring may

break it!

1.

REA 900A ONLY - Remove pneumatic and

fluid lines from the front of the bulkhead plate.

Remove the bulkhead plate.

2. Remove rear housing and two (2) springs.

3. Using an adjustable wrench on the flats of the

valve rod extension, remove the air valve adjusting,

and air valve lock nut.

4. Disconnect coiled fluid tube at the fluid inlet

fitting.

5. Loosen barrel nut with 19749-00 spanner

wrench.

6. Pull the barrel and automatic body

STRAIGHT

apart. Take extra care in handling barrel assembly

to prevent bending of the extension valve rod.

NOZZLE AND

ELECTRODE CLEANING

OR REPLACEMENT

(REA 9000R & 900A)

NOTE

> There is no need to remove retaining

ring or barrel nut from barrel unless they

are damaged. If they are to be removed,

lift one end of ring out of its groove and

spiral it off of the end of the barrel, then

barrel nut can be removed. To replace

them on the barrel, slide nut onto the bar-

rel, place ring against the back of the bar-

rel, lift one end of it onto the barrel and

spiral it on and into its groove.

C A U T I O N

!

>

NEVER bend the electrode!

NOTE

>

See “Atomizer Assembly Cleaning

Procedure” previously discussed in this

section.

Air Cap

1. Unscrew retaining ring, remove air cap from

barrel, and clean using proper method or replace it.

2. Replace air cap and tighten retaining ring back

onto the barrel.

W A R N I N G

!

>

NEVER shorten the electrode wire.

Ransburg

REA Automatic Applicators - Maintenance