BARREL TO BODY

ASSEMBLY

(REA 9000W)

1. Slide gasket over the rear end of the barrel

assembly. Lightly coat cascade high voltage con-

nections with LSCH0009-00 dielectric grease.

2. Tighten retaining ring with 19749-00 spanner

wrench.

> Nut should be secured hand tight only.

NEVER apply more than 10 lb•ft torque.

C A U T I O N

!

HIGH VOLTAGE MODULE

ASSEMBLY

REPLACEMENT

(REA 9000W Only)

1. Remove the voltage cable from the rear of the

high voltage module assembly.

2. Remove the high voltage module to barrel

mounting bracket.

3. Remove the four (4) 1/4-20 flat head screws

in the top of the probe holder body assembly.

Remove the probe AND body as ONE assembly.

!

> Turn

OFF all power, air and fluid at the source.

W A R N I N G

> The voltage cable

MUST be removed before

removing the high voltage module.

C A U T I O N

!

4. Remove module retaining screw from the top

of the module.

5. Remove the two (2) 1/4-20 screws that attach

the rear bulkhead plate to the high voltage module.

These screws are accessed through holes in the

sides of the bulkhead plate.

6. Pull the high voltage module STRAIGHT out

through the bulkhead plate.

7. Install new high voltage module and assembly

in reverse order.

> Generously lubricate probe body

metal plunger and high voltage module

contact bore with LSCH0009-00 dieletic

grease.

NOTE

LOW VOLTAGE CABLE

REPLACEMENT

(REA 900A Only)

Disassembly:

1. Using wrench on connector flats, disconnect

low voltage cable from connector assembly.

2. Disconnect other end of low voltage cable from

control unit and remove cable from system.

W A R N I N G

> Ensure control unit power is

OFF before dis-

connecting cable from applicator or control unit.

!

Ransburg

REA Automatic Applicators - Maintenance

31

AA-99-02.5