FLUSHING PROCEDURES
1. Turn the control unit power OFF.
2. Turn the paint supply OFF.
3. Turn the atomizing air supply OFF.
4. Activate dump air and flush with solvent until
it is clear of paint. Air purge the dump line.
5. De-activate dump air and activate trigger air
until the applicator fluid passage is clear.
6. Disconnect the solvent supply.
7. Activate the trigger valve until it is clear of
solvent. After the preceding steps are complete,
the applicator is ready for color change, storage
or service.