9

348002K/348012K Cool-Tech Recovery/Recycling/Recharging Unit

Operating Guidelines

USING THE SELECTION MENU

(continued)

FILTER WEIGHT

This function is used to show the operator how many pounds of refrigerant have
been recovered since the last filter change.

1. Select FILTER WEIGHT from the menu. Press

ENTER

.

2. The display shows amount of refrigerant recovered since last filter change.

3. If display reads greater than 300 lbs., go to MENU/CHANGE FILTER

4. Press

STOP

to exit.

SELECT PROMPT

Use the BASIC PROMPT option to receive step-by-step, on-screen prompting
through any procedure. Use ADVANCED PROMPT once you know the procedure
and no longer need the step-by-step routine.

1. Choose SELECT PROMPTS from the menu. Press

ENTER

.

2. Toggle between BASIC/ADVANCED using the

ARROW

keys.

3. Press

ENTER

to select the current choice.

SELECT AUTO RESTART

The AUTO RESTART ON option is used to automatically restart the unit if a
pressure rise is detected by the unit during the five minute waiting period after
recovering refrigerant. If AUTO RESTART OFF is selected, the operator must
watch the gauges for a pressure rise and manually restart the recovery process if a
pressure rise is detected.

1. Select AUTO RESTART. Press

ENTER.

2. Use

ARROW

keys to toggle between the two options.

3. Press

ENTER

to select the current choice.