Set up instructions, Set-up instructions, Installation routine – Robinair 348012K Recovery, Recycling, Recharging Unit User Manual

Page 7: Vacuum pump initial fill

Advertising
background image

5

348002K/348012K Cool-Tech Recovery/Recycling/Recharging Unit

Set Up Instructions

Set-Up Instructions

IMPORTANT!

Be sure the

pump is

running when

adding oil.

IMPORTANT

!

For maximum

performance, be

sure to change

the vacuum

pump oil

frequently.

1. Press

VACUUM

to get to the VACUUM mode. Press

START

to go into

VACUUM.

NOTE: The vacuum pump is shipped without oil in the reservoir. Before
starting the pump, oil must be added to the pump or damage may occur.

2. Close all manifold valves on the control panel.

3. Remove bolts holding the door closed and open the door.

4. Remove the black plastic plug from the fill port on the top of the vacuum

pump.

5. Attach the oil fill tube to the 16 oz. bottle of vacuum pump oil provided in the

accessory kit.

6. While the vacuum pump is running, add oil until it reaches the center of the

sight glass. Press

STOP

. The vacuum pump is now filled to the proper level

with oil.

7. Pour oil (approximately 12 oz.) into the fill port of the vacuum pump until the

oil appears at the bottom of the sight glass. Press

ENTER

.

8. Replace the plug in the fill port.

9. Press

STOP

to exit.

10. Close the door and replace the bolts holding the door shut.

INSTALLATION ROUTINE

1. Press

MENU

. Use the ARROW keys to go to the INSTALLATION

ROUTINE.

2. Press

ENTER

. The display toggles between CONNECT LS RXX HOSE TO

SOURCE TANK and TURN ALL VALVES TO VACUUM/RECOVER
AND PRESS START TO BEGIN. Follow the on-screen prompts.

3. Remove the service hoses from the accessory kit and remove

the plugs from the hoses using a pair of pliers.

4. Attach the service hoses to the high and low side bulkheads on the rear of the

unit. Attach the R-134a hoses to the left rear. Attach the R-12 hoses to the
right rear. Attach the RED hoses to the bulkheads labeled HIGH and the
BLUE hoses to the bulkheads labeled LOW.

VACUUM PUMP INITIAL FILL

1

3

2

INST0760

1. Oil Fill Port
2. Sight Glass
3. Oil Drain

Advertising