10. The unit then goes into automatic oil drain and the display reads OIL

DRAINING. Oil draining can require up to 90 seconds to complete.

11. After the oil drain is complete, the display alternates between:

RECOVERY COMPLETE

CHECK OIL BOTTLE.

RECOVERED XXX.XX lbs.

RECOVERED XXX.X lbs.

12. Check the oil drain bottle and note the amount of oil that was removed from

the A/C system. This is the amount of oil that must be charged into the A/C
system after evacuation is complete.

13. To ensure complete recovery of refrigerant, wait 5 minutes and watch the

manifold gauges for a rise in pressure above 0 in. Hg. A pressure rise may
occur if there was freezing in the A/C system during recovery. If a rise occurs,
press

START

to repeat the recovery process. Repeat as needed until the

system pressure holds for two minutes, then press

STOP

. The AUTO

RESTART ON option can be used to automatically restart the recycling
process if the unit detects a pressure rise after five minutes. See the Selection
MENU section for details. This process meets SAE Spec J2211.

14. Press

STOP

to exit.

Recovery is now complete. You are now ready to make any repairs to the A/C
system, if necessary, or advance to the Evacuation Process.