348002K/348012K Cool-Tech Recovery/Recycling/Recharging Unit

NOTE:

If any oil was drained from the system during recovery, DO NOT use the

VAC-CHG feature. The oil must be replenished into the A/C system, which is not
possible when the VAC-CHG function is used.

VACUUM

1. Press

ENTER

to accept the default evacuation time of 15:00 minutes or enter

the desired vacuum time by using the number keys (To enter 10 minutes, press
1 and 10:00 should appear on the display. To enter 1 minute, press 0 then press
1, and 1:00 should appear on the display).

2. Press

ENTER.

The unit evacuates the A/C system and stops when the

specified time has elapsed.

3. You are now ready to replenish the A/C system oil (if necessary) or to recharge

the system with refrigerant.

4. Press

STOP

to exit.

VAC-CHG

1. Press

CHARGE

to select the VAC-CHG feature.

2. Press

START

to charge the default amount of refrigerant (2.00lb) or use the

number keys to enter the desired charge weight. Then press

ENTER

.

3. If the weight entered leaves less than 5 lbs. of refrigerant in the external storage

vessel, the VAC-CHG process does not begin and the display reads LOW
REFRIGERANT. At this point, refrigerant must be added to the external
storage vessel. See the OPERATING GUIDELINES section of this manual for
external storage vessel refill instructions and then return to Step 1 of
EVACUATING THE A/C SYSTEM.

4. If the external storage vessel contains a sufficient amount of refrigerant, press

ENTER

to accept the default evacuation time of 15:00 minutes or enter the

desired vacuum time by using the number keys. Then press

ENTER

.

5. The unit automatically charges the A/C system after the specified vacuum time

has elapsed.

6. Advance to Step 6 of RECHARGING THE A/C SYSTEM in this manual to

complete the charging process.