© 2000 Robinair, SPX Corporation

4

Set-Up Instructions

INITIAL SET-UP

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

R-134a systems have special fittings (per SAE

specifications) to avoid cross-contamination with R-12 systems. Do

not attempt to adapt your unit for another refrigerant — system

failure will result! Read and follow all warnings at the beginning of

this manual before operating the unit.

CA

CA

CA

CA

CAUTION!

UTION!

UTION!

UTION!

UTION!

Avoid the use of an extension cord because the

extension cord may overheat. However, if you must use an

extension cord, use a No. 14 AWG minimum and keep the cord as

short as possible.

1. Lock both front casters of the unit by stepping on the cam brake levers, plug

the power cord into the power cord receptacle (Item 9 in the INST 0707
drawing on page 3). Turn on the MAIN POWER switch.

2. Press

MENU

.

3. Use the

UP

and

DOWN

arrows to select LANGUAGE SELECTION. Press

ENTER

.

4. Use the

UP

and

DOWN

arrows to scroll through the language options and

press

ENTER

to select a language and exit LANGUAGE SELECTION.

5. Press

MENU

. Use the ARROW keys to go to SELECT AUTO RESTART.

Press

ENTER

.

6. Use the

UP

and

DOWN

arrows to toggle between AUTO RESTART ON and

AUTO RESTART OFF. Press

ENTER

to select.

NOTE: See the Operating Guidelines section of this manual for a description of
these functions.

7. Press

MENU

. Use ARROW keys to go to SELECT PROMPT. Press

ENTER

.

8. Use the

UP

and

DOWN

arrows to toggle between BASIC PROMPTS and

ADVANCED PROMPTS. Press

ENTER

to select.

NOTE: See the Operating Guidelines section of this manual for a description of
these functions.

IMPORTANT

!

You must press

the MENU key to

access all the

functions.