Operating guidelines, Using the selection menu 1, Change filter – Robinair 348012K Recovery, Recycling, Recharging Unit User Manual

Page 8

Advertising
background image

© 2000 Robinair, SPX Corporation

6

Operating Guidelines

USING THE SELECTION MENU

1.

Press

MENU

. The top line of the display reads LANGUAGE SELECTION.

2. Use the

UP

and

DOWN

arrows to scroll through the menu choices. The menu

choices are (in order of appearance):

3. Press

ENTER

to make a choice from the menu. Press

STOP

to terminate any

process.

CHANGE FILTER

The filter-drier removes acid, particulates and water from the refrigerant. Change
the filter-drier after 150 pounds of refrigerant has been filtered. See the DRIER
RECOVERED LBS. section on the following page as well as the Maintenance
Section on page 20 for instructions.

1. LANGUAGE SELECT

2. CHANGE FILTER

3. FILTER WEIGHT

4. SELECT AUTO RESTART

5. MEASUREMENT UNITS

6. CHANGE VACUUM PUMP OIL

7. TANK FILL

8. VACUUM OIL TIME

9. INSTALLATION ROUTINE

10. SELECT PROMPTS

11. CHANGE DEFAULT (Password

Protected)

5. Press

START

. The unit automatically evacuates the system for 5:00 minutes

to remove any air from the external storage vessel (Ensure that all tank valves
are open).

IF THE SELECTOR SWITCH IS SET TO R-134A:

6. Connect the lowside service coupler to the source tank valve, using the

adapter supplied with the unit, when the 5:00 minute evacuation is complete.
Open the service coupler and turn manifold valves to RECOVER/VACUUM.

IF THE SELECTOR SWITCH IS SET TO R-12:

7. When the 5:00 minutes evacuation is complete, connect the low side hoses the

hose adapter supplied with the unit. Attach the adapter to the source tank.

Advertising