1 9

348002K/348012K Cool-Tech Recovery/Recycling/Recharging Unit

Operating Instructions

IMPORTANT!

You should

evacuate the A/C

system for at

least 15 minutes

for adequate

moisture and

contaminant

removal.

RECHARGING THE A/C SYSTEM

WARNING

1. Press

CHARGE

.

2. Accept either the default weight by pressing

START

or type in a weight with

the number keys and press

START

(For example, to program 3 lbs, press 3

and 3.00 lbs will appear on the display. To program 3.25 lbs, press 3-2-5, in
that order, and 3.25 lbs will appear on the display).

3. If the weight entered will leave less than 5 lbs. of refrigerant in the refrigerant

tank, the charge function will not start and the display will read:

LOW REFRIGERANT

Refrigerant XX.XX lbs.

See the Operating Guidelines section of the manual for refill instructions.

4. Close the Low Side valve. Place the High Side valve in the Oil Inject/Charge

position (Note: Use the valves corresponding with the refrigerant you are
working with).

5. Upon entering a valid charge weight, the display shows:

CHARGE MODE

AMT. CHARGED XX.XX lbs.

Press

START

to continue.

6. The display will say "Charge complete. Amt. charged XX.XX".

7. Close the high and low side coupler valves and remove the service

hoses from the A/C system.

8. Turn off the

MAIN POWER

switch.

The A/C system is now ready for use.

Always wear safety goggles when working with refrigerant. Use only

authorized refillable refrigerant tanks. Disconnect hoses with extreme

caution!
All hoses may contain liquid refrigerant under pressure. Read and follow

all warnings at the beginning of this manual before operating the unit.

Closed

Oil Inject/Charge

INST 0770

CORRECTING AN INCOMPLETE CHARGE

On ocassions the AMT. CHARGED will not finish. The reason for this is that the pressures

in the ESV and the A/C system have equaled. To finish the charge, you should:

1.

Turn high side valve on the control panel to the closed position.

2.

Turn low side valve on the control panel to recover/vacuum position.

3.

Start the vehicle and turn on the A/C.

4.

The remainder of the charge will be pulled into the A/C system and display
will read CHARGE COMPLETE.

Note: To add less than 1 pound of refrigerant, such as 0.25, press 0-2-5, in that order.