IMPORTANT!

You should

evacuate for at

least 15 minutes

to ensure

adequate moisture

and contaminant

removal.

Operating Instructions

EVACUATING THE A/C SYSTEM

WARNING

Always wear safety goggles when working with refrigerant. Use only

authorized refillable refrigerant tanks. Read and follow all warnings at the

beginning of this manual before operating the unit. In addition to the

number keys, the keypad contains special keys that accomplish specific

operating functions.

1. Connect the service hoses to the vehicle. R-134a users: Open the coupler

valves.

2. Place both High and Low Side manifold valves in Recover/Vacuum.

3. Turn the unit on and press

VACUUM

.

4. If the vacuum pump has been run more than 10 hours since the last oil change,

the display reads: VACUUM OIL TIME= X hr. Xmin. Xsec. Press

STOP

to

change the vacuum pump oil or press

START

to continue. Instructions for

changing the vacuum pump oil are located in the maintenance section of this
manual.

NOTE: Vacuum Pump oil should be changed after 10 hours of use to maintain
maximum performance and endurance levels.

5. If the system being evacuated contains a pressure over 25 psi at any point

during the evacuation, the display reads HIGH SYSTEM PRESSURE . This
message indicates that the A/C system contains refrigerant. Press

RECOVER

to continue. After recovery is complete, return to Step 1 to evacuate the A/C
system.

6. If the pressure is below 25 psi, the user is prompted to press

START

to

VACUUM or press

CHARGE

to use the VACUUM-CHARGE (VAC-CHG)

feature. If VACUUM is selected, the unit vacuums the system only and user
interaction is required to enter the CHARGE mode. If the VACUUM-
CHARGE feature is chosen, the unit automatically charges the system after
evacuation is complete.

IMPORTANT!

If the vacuum

pump has run for

10 or more hours

without an oil

change, the

message

VACUUM OIL

TIME = Xhr. Xmin

Xsec appears on

the display.

Change the

pump oil

following the

procedures in the

MAINTENANCE

INSTRUCTIONS.

Vacuum

INST 0726

The Control Panel During Evacuation

Valves Open

Advertising