BS-Serial in Orpan Modes

For a BS-Serial in Orpan (LSB first) mode, the menu will appear as follows. If an Eprom is found, the size

of the first show is displayed at the top of the screen. If no Eprom is found, the Ônot foundÕ will appear in
the place of the show size.

-Gilderfluke & Company - Serial Output Smart Brick - v1.05 - copyright 1999 DCM-

EPROM: 123 channels @ 30 FPS / first show is 12345 frames long

a) 1st address in Eprom- __1
b) baud rate- 38.4Kbaud
c) DMX Rx checksums- yes
d) sequencer enabled- yes
e) frame rate divided/2- no
f) numbering system- decimal
g) VT-52 display- yes
h) operating mode- Orpan (LSB first)

i) monitor channel- none

l) string trigger channel- none
m) edit strings....

o) reload defaults....
r) download configuration....

Enter Command-

For a BS-Serial in Orpan (MSB first) mode, the menu will appear as follows:

-Gilderfluke & Company - Serial Output Smart Brick - v1.05 - copyright 1999 DCM-

EPROM: 123 channels @ 30 FPS / first show is 12345 frames long

a) 1st address in Eprom- __1
b) baud rate- 38.4Kbaud
c) DMX Rx checksums- yes
d) sequencer enabled- yes
e) frame rate divided/2- no
f) numbering system- decimal
g) VT-52 display- yes
h) operating mode- Orpan (MSB first)

i) monitor channel- none

l) string trigger channel- none
m) edit strings....

o) reload defaults....
r) download configuration....

Enter Command-

In either of the Orpan modes, the first six axis of twelve bit analog data are sent out through the serial

port. The address of the first analog is always Ф01Х. When you save the Eprom files for using Orpan mode,
always start with channel Ф00Х and use a Ф00Х Eprom offset. The difference between the two modes is the
order in which the bytes are sent.