Gilderfluke&Co DMX-512, Serial, and MIDI Output Smart Bricks User Manual

Page 44

Advertising
background image

9

white

channel 0 data bit 0

10

black

+15 VDC unregulated power supply (fused for 1 amp)

11

brown

circuit ground

12

red

channel 1 data bit 7

13

orange

channel 1 data bit 6

14

yellow

channel 1 data bit 5

15

green

channel 1 data bit 4

16

blue

channel 1 data bit 3

17

violet

channel 1 data bit 2

18

gray

channel 1 data bit 1

19

white

channel 1 data bit 0

20

black

+15 VDC unregulated power supply (fused for 1 amp)

21

brown

circuit ground

22

red

channel 2 data bit 7

23

orange

channel 2 data bit 6

24

yellow

channel 2 data bit 5

25

green

channel 2 data bit 4

26

blue

channel 2 data bit 3

27

violet

channel 2 data bit 2

28

gray

channel 2 data bit 1

29

white

channel 2 data bit 0

30

black

+15 VDC unregulated power supply (fused for 1 amp)

31

brown

circuit ground

32

red

channel 3 data bit 7

33

orange

channel 3 data bit 6

34

yellow

channel 3 data bit 5

35

green

channel 3 data bit 4

36

blue

channel 3 data bit 3

37

violet

channel 3 data bit 2

38

gray

channel 3 data bit 1

39

white

channel 3 data bit 0

40

black

+15 VDC unregulated power supply (fused for 1 amp)

Any eight digital devices or one eight bit analog device can be connected to any 1/4 J-6 cable as

shown. The LED between the ground (pin #1 brown) wire and supply (pin #10 black) wire acts as an indi-
cator which is lit if the fuse for that channel is OK:

#1 ground (brown)--

#2 bit 7 (red)--

#3 bit 6 (orange)--

#4 bit 5 (yellow)--

#5 bit 4 (green)--

#6 bit 3 (blue)--

#7 bit 2 (violet)--

#8 bit 1 (grey)--

#9 bit 0 (white)--

#10 supply (black)--

load

load

load

load

load

load

load

load

#1 ground (brown)--

#2 bit 7 (red)--

#3 bit 6 (orange)--

#4 bit 5 (yellow)--

#5 bit 4 (green)--

#6 bit 3 (blue)--

#7 bit 2 (violet)--

#8 bit 1 (grey)--

#9 bit 0 (white)--

#10 supply (black)--

any

eight bit

analog

device

LED

2.2 K ohm

1/4 watt resistor

The supply line for each 1/4 J-6 is fused for 1 amp. You should treat each 1/4 J-6 as an individual, and

not cross the outputs or supply lines from one channel to the lines from any other channel. Doing this
wonÕt cause any damage, but can reduce the protection for the outputs that the fuses normally provide.

The current Output Capacity of a each output is as shown in the following chart:

G