Printer Port Connections and Communications:

The Intelligent PA System supports a single ÔPRINTER OutputÕ port. This can be attached to a printer or

CRT to log selected PA System activity. Connections to this serial port are similar to those used for the
TERMINAL Input port, except that instead of a data input line the printer port supports only a handshaking
line.

The Printer Output is also 6 position RJ-11 (modular telephone style connector). Facing the end of

the cable with the release latch upwards, its pin out is as follows:

COLOR

Signal NAME:

LEFT

White

Signal Ground

Black

- Serial Data OUT FROM PA SYSTEM

Red

+ Serial Data OUT FROM PA SYSTEM

Green

- Clear to Send IN to PA SYSTEM

Yellow

+ Clear to Send IN to PA SYSTEM

RIGHT

Blue

Signal Ground

The printer port is set for 9600 baud, 8 bits of data, 1 stop bit, no parity.