Connections – Gilderfluke&Co PA System User Manual

Page 35

Advertising
background image

- Connections -

- Terminal input -

- RJ-11 / 6 Position Modular Telephone Connector -

- RS-485 Serial Data -

1

White

Ground

2

Black

+ Tx Data from MA-100

3

Red

- Tx Data from MA-100

4

Green

+ Rx Data into MA-100

5

Yellow

- Rx Data into MA-100

6

Blue

Ground

- Printer output -

- RJ-11 / 6 Position Modular Telephone Connector -

- RS-485 Serial Data -

1

White

Ground

2

Black

+ Tx Data from MA-100

3

Red

- Tx Data from MA-100

4

Green

+ Rx Clear to Send into MA-100

5

Yellow

- Rx Clear to Send into MA-100

6

Blue

Ground

- PA Station Connections -

- RJ-45 / 8 Position Modular Telephone Connector -

- Audio, Power and RS-485 Serial Data -

1

Gray

+ RS-422 Serial Data

2

Orange

- RS-422 Serial Data

3

Black

+ 27 to 35 VDC Supply

4

Red

Supply Ground

5

Green

Supply Ground

6

Yellow

+ 27 to 35 VDC Supply

7

Blue

Balanced Audio Signal

8

Brown

Balanced Audio Signal

- PA Microphone Connections -

- 4 Position Female XLR Connector -

- Microphone and PTT Switch -

1

Microphone

2

Microphone

3

Push To Talk (PTT) switch

4

Push To Talk (PTT) switch

- 'Single Channel BGM Input' -

- 3 Pin Female XLR Connector -

- Background Music (BGM) Input used when Connector below is not -

1

Ground

2

+ Input

Balanced Audio Line Level

3

- Input

Balanced Audio Line Level

G

ILDERFLUKE

& C

O

. ¥ 205 S

OUTH

F

LOWER

S

T

. ¥ B

URBANK

, C

ALIF

. 91502-2102 ¥ 818/840-9484 ¥

FAX

818/840-9485

31 of 35